11 — Electrical & Electronics
Three Phase Auto Transformer
A variable three-phase autotransformer used to supply an adjustable three-phase AC voltage for machine and power-system laboratory experiments.
01 — Same Laboratory
More in Electrical Machines
-
024
Four-Point Starter for DC Motor
A starting device used to limit inrush armature current and provide overload and no-volt protection while starting a DC motor.
-
025
Induction Motor Coupled DC Shunt Generator Set
A motor-generator set pairing an induction motor with a DC shunt generator, used to study load characteristics and power conversion between an AC drive and DC generation.
-
026
Single Phase 1 HP Induction Motor
A 1 HP single-phase induction motor used in electrical machines laboratories to perform load tests, speed-torque studies, and starting-method demonstrations.
-
027
Single Phase Auto Transformer
A variable single-phase autotransformer (variac) used to supply an adjustable AC voltage for laboratory experiments and equipment testing.
-
028
Single Phase Transformer (1 kVA)
A 1 kVA single-phase transformer used to perform open-circuit and short-circuit tests, load testing, and efficiency and regulation calculations.
-
029
Single Phase Universal Motor
A single-phase universal motor that runs on both AC and DC supply, used to study its speed-torque behavior and series-motor characteristics.
-
031
Three Phase Transformer (5 kVA)
A 5 kVA three-phase transformer used for load testing, vector-group verification, and efficiency and regulation studies in an electrical machines laboratory.
-
032
Three Point Starter for DC Motor (230V, 10A)
A 230 V, 10 A three-point starter used to limit starting current and safely start a DC shunt or compound motor.
-
033
Transformer Workbench
A dedicated workbench fitted with meters, switches, and terminals for connecting and testing single- and three-phase transformers in laboratory experiments.
-
034
Digital Stroboscope
A digital stroboscope that produces calibrated flashes of light synchronized to a rotating shaft, used to measure rotational speed without physical contact.
-
035
Inductive Load Bank
A bank of switchable inductive elements used to apply a controllable inductive load to a power supply, generator, or motor for laboratory testing.
-
036
Three Phase Variable Resistive Load (Rheostat Bank)
A bank of three-phase variable resistors used to apply an adjustable resistive load to generators, motors, and transformers during laboratory testing.
Need Three Phase Auto Transformer?
Tell us your requirement and we will get back to you.