11 — Electrical & Electronics

Digital Tachometer

Contact and non-contact digital tachometer for measuring the speed of rotating machines during load and speed-control tests. Reads in revolutions per minute with hold and peak-memory functions.

Send Enquiry

01 — Same Laboratory

More in Electrical Machines

  • 035

    Inductive Load Bank

    A bank of switchable inductive elements used to apply a controllable inductive load to a power supply, generator, or motor for laboratory testing.

  • 036

    Three Phase Variable Resistive Load (Rheostat Bank)

    A bank of three-phase variable resistors used to apply an adjustable resistive load to generators, motors, and transformers during laboratory testing.

  • 037

    Three Phase Synchronous Motor Coupled with DC Shunt Generator Set

    A motor-generator set pairing a three-phase synchronous motor with a DC shunt generator, used to study synchronous motor starting, loading, and power conversion.

  • 038

    DC Shunt Motor-Generator Set

    Coupled DC shunt motor and DC generator on a common bed-plate with starter, field regulators and instrumentation. Used for load tests, speed control, efficiency determination and Swinburne's test.

  • 039

    DC Series Motor

    Laboratory DC series motor with terminal box and mechanical loading arrangement for plotting speed-torque and speed-current characteristics. Demonstrates the high starting torque and no-load runaway behaviour of series excitation.

  • 040

    DC Compound Motor

    DC compound-wound motor allowing cumulative and differential connection so students can compare compound characteristics against shunt and series machines. Supplied with loading arrangement and instrumentation.

  • 041

    Three-Phase Squirrel Cage Induction Motor

    Laboratory squirrel-cage induction motor with accessible terminals for star-delta connection, no-load and blocked-rotor tests and load testing. The standard machine for induction-motor performance experiments.

  • 042

    Three-Phase Slip Ring Induction Motor

    Wound-rotor induction motor with brush gear and external rotor resistance for demonstrating rotor-resistance starting and speed control. Used for slip, torque and speed-control practicals.

  • 043

    Three-Phase Alternator / Synchronous Generator

    Three-phase alternator with separate excitation for open-circuit and short-circuit tests, regulation by the EMF and MMF methods, and parallel operation. Core machine of the synchronous-machines laboratory.

  • 044

    Three-Phase Synchronous Motor

    Synchronous motor with DC excitation and loading arrangement for plotting V-curves and inverted V-curves and demonstrating power-factor correction by over-excitation. Supplied with starting arrangement and instrumentation.

  • 045

    Brake / Dynamometer Loading System

    Mechanical loading arrangement — rope brake, eddy-current or electromagnetic dynamometer — with spring balances or torque readout for loading motors under test. Enables torque, output-power and efficiency measurement.

  • 047

    Electrical Machine Test Bench

    Modular bench carrying a machine bed-plate, coupling guard, starters, variable supplies, loading and metering so DC and AC machines can be tested from one station. Consolidates the machines laboratory into a repeatable set-up.

All 291 Items in Electrical & Electronics

Need Digital Tachometer?

Tell us your requirement and we will get back to you.